In case your furnace has a pilot mild, you might have to relight it sometimes. This can be a comparatively easy process that you are able to do your self. Nevertheless, you will need to comply with the steps fastidiously to keep away from any accidents.
Earlier than you begin, be sure that the furnace is turned off. You must also open a window or door to make sure that there’s loads of air flow. Then, find the pilot mild meeting. That is often a small, metallic tube with a flame burning inside. There shall be a knob or lever that you should use to show the fuel on and off.
Upon getting positioned the pilot mild meeting, it’s worthwhile to flip the fuel on. To do that, flip the knob or lever clockwise till you hear a click on. You might also have to press a button to ignite the flame. As soon as the flame is lit, you may regulate the knob or lever to manage the dimensions of the flame.
Figuring out the Pilot Gentle
Finding the pilot mild in your furnace is important earlier than making an attempt to mild it. This is an in depth information that can assist you determine the pilot mild:
- Find the Furnace: The furnace is often positioned within the basement, utility room, or attic. It is often a big metallic field with pipes and wires hooked up.
- Entry the Burner Meeting: Open the entry panel or door on the furnace to show the burner meeting. That is the place the pilot mild is often positioned.
- Determine the Pilot Gentle: The pilot mild is often a small, flame-like burner on the base of the burner meeting. It could be positioned subsequent to a fuel valve or igniter change.
- Distinguish from Different Flames: If you happen to see a number of flames within the burner meeting, be sure to determine the proper one. The pilot mild is often the smallest and most regular flame.
- Test for a “P” Marking: Some pilot lights have a “P” image or marking etched on them to assist determine them simply.
Search for a small, blue flame. |
Test the placement close to a fuel valve or igniter change. |
Distinguish from bigger, flickering flames. |
Test for a “P” marking on the pilot mild. |
Finding the Fuel Valve
To find the fuel valve to your furnace, comply with these steps:
-
Discover the furnace.
The furnace is often positioned in a basement, attic, or utility closet. It’s a giant metallic field with a blower fan and a burner. -
Search for the fuel line.
The fuel line is a metallic pipe that runs to the furnace. Will probably be linked to a valve on the facet of the furnace. -
Determine the fuel valve.
The fuel valve is a small, brass-colored valve that’s positioned on the fuel line. It’ll have a lever or a deal with that you should use to show it on and off.
Kind of Fuel Valve | Location |
---|---|
Guide Fuel Valve | On the fuel line, close to the furnace |
Automated Fuel Valve | Contained in the furnace, close to the burner |
Turning Off the Fuel Provide
Earlier than you start working in your furnace, it is important to show off the fuel provide. It will forestall any fuel from leaking out and doubtlessly inflicting a fireplace or explosion.
To show off the fuel provide, comply with these steps:
- Find the fuel valve. It is sometimes positioned close to the furnace or on the fuel line main into the furnace.
- Flip the fuel valve to the “off” place. That is often finished by turning the valve clockwise.
- Test the fuel line for any leaks. To do that, apply a soapy water resolution to the fuel line. If you happen to see any bubbles forming, there is a leak. Restore the leak earlier than continuing.
As soon as you have turned off the fuel provide, you may safely proceed with lighting the pilot in your furnace.
Fuel Valve Place | Description |
---|---|
Open | Permits fuel to move by means of the valve |
Closed | Prevents fuel from flowing by means of the valve |
Lighting the Pilot with a Match
To mild the pilot in your furnace with a match, comply with these steps:
-
Collect your supplies.
You’ll need a lighter or match, a long-handled lighter or match holder, and a screwdriver (non-obligatory).
-
Find the pilot mild meeting.
The pilot mild meeting is often positioned on the underside of the furnace. It’ll have a small, spherical window and a fuel valve.
-
Flip off the fuel provide.
Find the fuel valve on the fuel line resulting in the furnace. Flip the valve clockwise to show off the fuel provide.
-
Gentle the pilot mild.
-
Utilizing a long-handled lighter or match holder, mild a match or lighter.
-
Maintain the flame close to the pilot mild meeting.
The pilot mild ought to ignite inside just a few seconds.
-
If the pilot mild doesn’t ignite, repeat steps 4a and 4b.
If the pilot mild nonetheless doesn’t ignite, you might want to make use of a screwdriver to regulate the fuel valve. Flip the valve counterclockwise barely to extend the fuel move.
-
-
Activate the fuel provide.
As soon as the pilot mild is lit, flip the fuel valve counterclockwise to activate the fuel provide.
-
Regulate the pilot mild flame.
The pilot mild flame needs to be about 1/2 inch lengthy. If the flame is simply too lengthy, it could trigger the furnace to overheat. If the flame is simply too quick, it could exit.
-
Reassemble the furnace.
As soon as the pilot mild is lit and adjusted, reassemble the furnace by closing the entry panel.
Lighting the Pilot with an Digital Igniter
In case your furnace has an digital igniter, lighting the pilot is a comparatively easy course of. Listed below are the steps it’s worthwhile to comply with:
1. Flip Off Fuel Provide
Earlier than you begin, flip off the fuel provide to the furnace. That is often finished by turning a valve positioned on the fuel line.
2. Discover the Pilot Meeting
The pilot meeting is often positioned close to the underside of the furnace. It’ll have a small, spherical window by means of which you’ll see the pilot flame.
3. Flip the Igniter Swap to “On”
Find the igniter change on the furnace. It’ll often be a small, purple or black button. Flip the change to the “On” place.
4. Press and Maintain the Reset Button
As soon as the igniter change is turned on, press and maintain the reset button. This button is often positioned close to the igniter change. Maintain the button for about 30 seconds.
5. Observe the Pilot Flame
After about 30 seconds, it’s best to see the pilot flame ignite. If the flame doesn’t ignite, wait a couple of minutes and check out once more. If the flame nonetheless doesn’t ignite, there could also be an issue with the igniter or the fuel provide. Contact a certified technician for help.
As soon as the pilot flame is ignited, launch the reset button. The flame ought to stay lit, and the furnace ought to begin heating.
Here’s a desk summarizing the steps for lighting the pilot with an digital igniter:
Step | Motion |
---|---|
1 | Flip off fuel provide. |
2 | Discover the pilot meeting. |
3 | Flip the igniter change to “On”. |
4 | Press and maintain the reset button for 30 seconds. |
5 | Observe the pilot flame. |
Adjusting the Pilot Flame
As soon as you have efficiently lit the pilot flame, it is vital to regulate it for optimum efficiency. Listed below are the steps to take action:
1. Flip On the Fuel Valve
Find the fuel valve on the furnace and switch it on by turning it counterclockwise. You need to hear a clicking sound because the fuel flows into the pilot meeting.
2. Gentle the Pilot Flame
Observe the directions within the earlier part to mild the pilot flame utilizing a long-reach lighter or match. Maintain the flame close to the pilot orifice till the burner lights up.
3. Regulate the Pilot Flame
Find the pilot adjustment screw close to the pilot burner. It is sometimes a small screw with a slotted or Phillips head.
4. Use a Screwdriver
Utilizing a screwdriver, gently flip the pilot adjustment screw clockwise or counterclockwise till the pilot flame is roughly 3/4 inches lengthy. That is the optimum flame measurement for many furnaces.
5. Test the Flame Coloration
The pilot flame needs to be blue in coloration. A yellow or orange flame signifies incomplete combustion and needs to be adjusted till it burns blue.
6. Observe the Flame Stability
The pilot flame needs to be steady and steady. If it sparkles or goes out intermittently, it could point out a fuel provide subject or different issues with the furnace. On this case, it is best to name a certified technician for inspection and restore.
Pilot Flame Coloration | Indication |
---|---|
Blue | Optimum combustion |
Yellow/Orange | Incomplete combustion, regulate flame |
Relighting a Extinguished Pilot
In case your furnace’s pilot mild has gone out, you may relight it your self by following these steps:
1. Flip off the fuel provide to the furnace.
2. Wait 5 minutes for the fuel to dissipate.
3. Find the pilot mild meeting.
4. Push within the reset button.
5. Maintain down the ignition button and light-weight the pilot mild with a match or lighter.
6. Launch the ignition button and maintain the reset button for 30 seconds.
7. Activate the fuel provide to the furnace.
If the pilot mild stays lit, your furnace is able to use. If the pilot mild goes out once more, there could also be an issue with the furnace that must be repaired by a certified technician.
Doable Causes of Pilot Gentle Extinguishment | Options |
---|---|
Clogged or soiled pilot mild orifice |
Clear the orifice with a small brush or wire. |
Defective thermocouple or thermopile |
Change the thermocouple or thermopile. |
Blocked fuel line |
Clear the blockage from the fuel line. |
The way to Gentle Pilot on Furnace
1. **Find the pilot mild meeting.** It’s often positioned close to the underside of the furnace.
2. **Flip off the fuel provide to the furnace.** That is often finished by turning a valve positioned close to the fuel meter.
3. **Wait a couple of minutes for the fuel to dissipate.** It will assist to stop an explosion.
4. **Use an extended lighter or match to mild the pilot mild.** Maintain the flame close to the pilot mild meeting and activate the fuel provide.
5. **Preserve the flame on the pilot mild for about 30 seconds.** It will enable the pilot mild to ignite and keep lit.
6. **Activate the furnace.** The furnace ought to now begin to warmth up.
Troubleshooting Widespread Pilot Gentle Points
8. The pilot mild will not keep lit.
**Doable causes:**
- The thermocouple is soiled or broken.
- The fuel provide shouldn’t be turned on all the way in which.
- The pilot mild meeting shouldn’t be correctly adjusted.
Options:
- Clear or exchange the thermocouple.
- Activate the fuel provide all the way in which.
- Regulate the pilot mild meeting in line with the producer’s directions.
If you’re having bother lighting the pilot mild in your furnace, you will need to name a certified technician. A technician can diagnose the issue and be sure that your furnace is working safely.
Security Precautions for Lighting a Pilot Gentle
Earlier than making an attempt to mild a pilot mild, make sure you comply with these essential security precautions to attenuate dangers:
1. Test for Fuel Leaks
Previous to igniting the pilot mild, examine all fuel traces and connections for any leaks. Use a soapy water resolution and apply it to the suspected areas. Bubbles point out a leak, requiring fast restore by a certified technician.
2. Clear Obstructions
Confirm that the pilot meeting and its environment are free from particles or blockages. Guarantee there’s correct airflow to facilitate ignition.
3. Ventilate the Space
Open home windows and doorways to make sure enough air flow throughout the lighting course of. This prevents fuel accumulation and potential hazards.
4. Extinguish Flames
Guarantee there aren’t any open flames or smoking supplies close to the pilot mild space. Exterminate any potential sources of ignition.
5. Follow Warning
By no means try and mild a pilot mild if you’re inexperienced or have any doubts. Search help from a certified technician.
6. Shield Your self
Put on acceptable security gear similar to gloves and security glasses to guard towards potential sparks or sizzling surfaces.
7. Observe Producer’s Directions
Check with the producer’s directions for particular procedures on lighting the pilot mild to your specific furnace mannequin.
8. Use the Appropriate Instruments
Make use of the suitable instruments for igniting the pilot mild, similar to a long-reach lighter or a spark igniter.
9. Lighting the Pilot Gentle
Observe these detailed steps to securely mild the pilot mild:
- Find the fuel management valve and switch it to the “Off” place.
- Find the pilot meeting and the ignition button.
- Depress the ignition button and maintain it whereas concurrently opening the fuel management valve barely.
- Observe the pilot mild by means of the viewing window and make sure if it ignites.
- Preserve the ignition button depressed for about 30 seconds to permit the thermopile to warmth up.
- Launch the ignition button and verify if the pilot mild stays lit.
- If the pilot mild extinguishes after releasing the ignition button, fastidiously repeat steps 4-6.
- If unsuccessful after a number of makes an attempt, contact a certified technician for help.
- As soon as the pilot mild is lit, regulate the fuel management valve to the specified flame top.
Keep in mind to comply with these security precautions and lighting directions diligently to attenuate dangers and make sure the secure and environment friendly operation of your furnace.
Examine and Clear
Repeatedly verify the pilot meeting for any dust, particles, or corrosion. Clear the thermocouple and pilot tube utilizing a comfortable brush or compressed air. This helps guarantee correct fuel move and ignition.
Test Fuel Strain
Utilizing a manometer, measure the fuel strain on the pilot mild. It needs to be inside the specified vary to your furnace. If the strain is simply too low or excessive, regulate it accordingly to make sure optimum flame stability.
Clear Obstructions
Be certain that there aren’t any obstructions blocking the air consumption or exhaust vents of the furnace. Clear any particles or mud that will hinder correct air circulation and stop the pilot mild from staying lit.
Keep Correct Airflow
Ample airflow is essential for a steady pilot mild. Examine and clear the blower motor and filter to make sure they’re functioning correctly and offering adequate air circulation all through the system.
Tighten Connections
Over time, connections can turn into free, inflicting fuel leaks and interfering with the pilot mild. Tighten all fuel line connections, together with these on the pilot meeting, fuel valve, and thermocouple.
Change Thermocouple
The thermocouple generates a small electrical present that retains the fuel valve open. If the thermocouple fails, the fuel valve is not going to open, and the pilot mild will exit. Change the thermocouple if it turns into defective.
Regulate Pilot Flame
The pilot flame needs to be a small, regular blue flame. If the flame is simply too giant, it could possibly overheat the thermocouple, inflicting it to fail. If the flame is simply too small, it could not generate sufficient present to maintain the fuel valve open. Regulate the pilot flame utilizing the adjustment screw on the fuel valve.
Examine Warmth Exchanger
A cracked or broken warmth exchanger can launch harmful carbon monoxide into the air. Periodically examine the warmth exchanger for any cracks or leaks, and have it repaired or changed if needed.
Use Permitted Gas
Solely use the kind of gasoline specified within the furnace guide. Utilizing an incompatible gasoline can injury the pilot meeting and result in combustion issues.
Name a Certified Technician
If you’re uncomfortable performing any of those duties or encounter any difficulties, it’s advisable to contact a certified HVAC technician who can safely and successfully preserve your furnace’s pilot mild.
How To Gentle Pilot On Furnace
In case your furnace shouldn’t be working, one of many first issues it’s best to verify is the pilot mild. The pilot mild is a small flame that ignites the fuel in your furnace. If the pilot mild shouldn’t be lit, your furnace will be unable to provide warmth.
To mild the pilot mild, you’ll need an extended match or a lighter. First, find the pilot mild meeting. It’s often positioned on the backside of the furnace. Upon getting discovered the pilot mild meeting, flip the fuel valve to the "off" place. It will cease the move of fuel to the pilot mild.
Subsequent, use the lengthy match or lighter to ignite the pilot mild. Maintain the match or lighter as much as the pilot mild and switch the fuel valve to the "on" place. The pilot mild ought to ignite instantly. If it doesn’t ignite, strive once more.
As soon as the pilot mild is lit, flip the thermostat to the specified temperature. The furnace will now begin to produce warmth.
Folks Additionally Ask
How do I do know if my furnace pilot mild is out?
In case your furnace shouldn’t be producing warmth, the pilot mild could also be out. You possibly can verify the pilot mild by wanting by means of the sight glass on the furnace. If the pilot mild shouldn’t be lit, it’s going to seem darkish.
Why will not my furnace pilot mild keep lit?
There are just a few explanation why your furnace pilot mild could not keep lit. One cause is that the thermocouple could also be defective. The thermocouple is a tool that senses the presence of the pilot mild and sends a sign to the fuel valve. If the thermocouple is defective, it will be unable to ship a sign to the fuel valve, and the fuel valve will shut off the move of fuel to the pilot mild.
One more reason why your furnace pilot mild could not keep lit is that the fuel strain could also be too low. If the fuel strain is simply too low, the pilot mild will be unable to remain lit. You possibly can verify the fuel strain by utilizing a manometer.
Lastly, your furnace pilot mild could not keep lit if the venturi tube is clogged. The venturi tube is a small tube that mixes air with fuel. If the venturi tube is clogged, the pilot mild will be unable to get sufficient air to remain lit. You possibly can clear the venturi tube by utilizing a small brush.